Page 11 - Zastrzały TITAN
P. 11
Table of permissible loads
Type Total Permissible axial load Individual parts Weight
length
in in BKS spindle BKS extension Butt
from – to compression tension element joints*
[m] [kN] [kN] [kg]
1.15 – 1.85 m short long
min. L half L max. L 2.40 m 3.70 m
BKS 1 2.3 - 3.7 50.0 50.0 50.0 50.0 2 - - 1 72
BKS 2 4.7 - 6.1 50.0 50.0 41.5 50.0 2 1 - 2 122
BKS 3 6.0 - 7.4 50.0 50.0 37.4 50.0 2 - 1 2 144
BKS 4 7.1 - 8.5 50.0 45.3 32.6 50.0 2 2 - 3 172
BKS 5 8.4 - 9.8 50.0 39.1 28.2 50.0 2 1 1 3 194
BKS 6 9.7 - 11.1 45.7 33.2 23.8 50.0 2 - 2 3 216
BKS 7 10.8 - 12.2 39.0 28.3 20.1 50.0 2 2 1 4 244
BKS 8 12.1 - 13.5 32.5 23.8 16.7 50.0 2 1 2 4 266
BKS 9 13.2 - 14.6 25.1 19.9 13.7 50.0 2 3 1 5 294
BKS 10 14.5 - 15.9 19.3 15.9 11.2 50.0 2 2 2 5 316
BKS 11 15.8 - 17.2 14.6 11.9 9.1 50.0 2 1 3 5 338
BKS 12 17.1 - 18.5 10.8 8.7 6.8 50.0 2 - 4 5 360
*4 No. bolts per butt joint M 16 x 60 (10.9 galv.) required
Historic façade retention
Prague, Czech Republic
11
10 11
10